The RJ45 termination connector for the data bus included in the scope of delivery must be pre-assembled on site. To do this, a wire jumper must be inserted and crimped between pins 1 and 6 (view from above onto the flat connector side with the pin contact surfaces, cable entry facing down, pins ascending from left to right). An actual resistor is not required.
Wichtige technische Daten
Dangerous goods transportation category | 2 |
---|---|
Dangerous goods description | LITHIUM ION BATTERIES |
Tunnel restriction code | (E) |
Classification code | M4 |
Dangerous goods class | 9 |
Dangerous goods packaging type | 4G |
UN No. | 3480 |
Dangerous goods Weight (net) (kg) | 289.100 |
Downloads
-
Battery-Box HVM+0161505
-
SMART ENERGY METER G20151118
-
PLENTICORE G3 – L0155067
-
B-Box HV-BCU + Base0161507
-
SMART ENERGY METER G20151118
-
PLENTICORE G3 – L0155067
Technical details
Topology | transformerless |
---|---|
Decibel | 39 |
Surge protection DC | no |
Backup system full | yes with supply |
Backup system light | no |
Display | with display |
Arc Fault Circuit Interrupter | no |
Number of independent MPPT (pcs) | 3 |
Min. temperature ambient (°C) | -10 |
Start input voltage (V) | 95 |
Max. short circuit current per MPPT (A) | 42 |
Max. input voltage DC (V) | 1000.00 |
Usable capacity (kWh) | 19.32 |
Max. output current (A) | 32.00 |
Rapid shutdown | no |
Capacity extendable later | yes without restriction |
Max. AC power (kVA) | 15.00 |
Surge protection AC | no |
Battery voltage | High Voltage |
Max. short circuit current (A) total | 126.00 |
Max. efficiency (%) | 98.00 |
Battery cell chemistry | LFP |
Integrated DC switch | yes |
Max. input current per MPPT (A). | 30 |
Max. generator power DC (kWp) | 22.50 |
MPP max. voltage range input (V) | 800.00 |
Offgrid usable | no |
Protection degree | IP55 |
Total number of string inputs | 3 |
AC nominal power (kW) | 15.00 |
Contact ripple control receiver | yes |
Integrated AC switch | no |
Contact for self-consumption optimization (e.g. for heat pump) | 4 |
European efficiency (%) | 97.00 |
Max. input current DC (A) total | 90.00 |
MPP min. voltage range input (V) | 170.00 |
Shadow management | yes |
Intrastat country of origin | China |
---|---|
Manufacturer item name | HVM+ 19.3*PLENTICORE L G3 |
Dangerous goods transportation category | 2 |
Dangerous goods description | LITHIUM ION BATTERIES |
Manufacturer | BYD + Kostal |
Tunnel restriction code | (E) |
Classification code | M4 |
Intrastat product number (HS-code) | 85076000 |
Dangerous goods class | 9 |
Dangerous goods packaging type | 4G |
UN No. | 3480 |
Dangerous goods Weight (net) (kg) | 289.100 |
Weight incl. packaging (Kg) | 352.600 |
---|
Weight without packaging (kg) | 328.800 |
---|