PowerKeeper ST050CF + SH125CX-V11

Skip product gallery

Matching accessories

Set
3-PHASE METER DTSU666-20
Sungrow
0154200
3-PHASE METER DTSU666-20 for indirect measurement, 3-phase
Set
Current transformer set 333mV, 250A
Sungrow
0154213
Current transformer set 333mV, 250A 3 x CT for DTSU666-20 or Energy Bridge
Set
Logger 1000A-EU V11
Sungrow
0157761
Logger 1000A-EU V11 for up to 30 devices
Set
COM100D-EU Smart Communication Box
Sungrow
0157762
COM100D-EU Smart Communication Box Logger for up to 30 devices
Set
PowerKeeper ST050CF Satelite
Sungrow
0164195
PowerKeeper ST050CF Satelite HV-storage, 49.9 kWh, LFP
Set
3-PHASE METER DTSD1352-C/1(6)A
Sungrow
0150242
3-PHASE METER DTSD1352-C/1(6)A 3-phase energy meter, indirect measurement
Product details

Product information "PowerKeeper ST050CF + SH125CX-V11"

The manufacturer’s specifications regarding the installation site, assembly, installation, required tools, fire protection, safety clearances, etc., must be reviewed and confirmed by the client/on-site team in advance.

A minimum of 4 storage modules is required per unit. All towers within a single unit must have the same voltage level and overall height.

A PowerKeeper Combiner Box is required for the parallel connection of up to 4 storage units.

Heated and non-heated battery modules must not be mixed within the same unit. When using multiple storage units with a BAT Combiner Box, both types may be used; however, the heating function will not be operational in this configuration.

For the entire system (existing + new), please verify whether additional data loggers or third-party Energy Management Systems (EMS) are required to support the necessary interfaces.

Appropriate lifting and transport equipment must be provided on-site. The accessibility of transport routes and passageways must be verified in advance.
Need to tuck nearly 1,000 kWh of modular storage capacity into a corner? And with no single component weighing more than 100 kg? The Sungrow PowerKeeper C&I storage system makes it possible. Its modular, cable-free stacking design ensures minimal installation effort while offering maximum versatility. Each 12.48 kWh battery module can be stacked five high per tower, with up to four towers connected in parallel to create a single unit with a capacity of nearly 250 kWh. By using a combiner box to cascade four of these units, you can reach an impressive 1,000 kWh. The system pairs perfectly with the Sungrow SH125CX C&I hybrid inverter, which features 10 MPP trackers and an integrated backup connection with a switching time of less than 10 ms. Beyond standard use cases, the system also supports advanced features such as smart trading, dynamic electricity pricing, and virtual power plant (VPP) integration. 

Product Advantages:
• Modular C&I (commercial & industrial) storage system
• Up to 1000 kWh in the maximum configuration
• Expandable at any time (no time limit for expansion)

Inverter Specifications:
• Nominal AC power: 125.0 kW
• Grid connection phases: 3
• AC grid voltage: 400 V
• Number of MPPTs: 10
• Max. DC input voltage: 1100 V
• DC surge protection: Type 1+2
• AC surge protection: Type 2
• AFCI (Arc-Fault Circuit Interrupter): Yes (version 3.0)
• DC connector type: Stäubli MC4
• Battery voltage level: High-voltage
• Communication: Wi-Fi, LAN, RS485, CAN, 2 x DI, 3 x DO
• Protection rating: IP66
• Cooling: Active
• Dimensions: 1095 x 795 x 360 mm
• Weight: 128.0 kg
• Warranty: 5 years

Storage Specifications:
• Capacity (usable): 49.9 kWh
• Storage type: High-voltage
• Expansion timeframe: Unlimited
• Number of storage modules per tower/unit: 5 / 20
• Max. number of units in parallel: Up to 4 (combiner box required)
• Cell chemistry: LFP (Lithium Iron Phosphate)
• Communication: CAN
• Cooling: Air-cooling
• Integrated cell heating: No
• Protection rating: IP66
• Cooling: Active
• Dimensions: 800 x 1567 x 405 mm
• Weight: 430.0 kg


Scope of Delivery:
• 1 x Sungrow SH125CX Hybrid Inverter (Item 0164090)
• 1 x Sungrow PowerKeeper Accessory Kit Master, incl. BMS + base (Item 0164089)
• 4 x Sungrow PowerKeeper battery module (Item 0164086)

Caution

Dangerous goods description LITHIUM ION BATTERIES
Dangerous goods Weight (net) (kg) 276.000
Dangerous goods class 9
Dangerous goods transportation category 2
UN No. 3480
Dangerous goods packaging type 4G
Classification code M4
Tunnel restriction code (E)

Technical details

AC nominal power (kW) 125.00
Surge protection AC type 2
Number of independent MPPT (pcs) 10
Arc Fault Circuit Interrupter yes
Surge protection DC type 1 and type 2
Display with display
European efficiency (%) 98.30
Protection degree IP66
Total number of string inputs 20
Commercial system yes
Integrated DC switch yes
Max. AC power (kVA) 125.00
Max. output current (A) 189.90
Max. generator power DC (kWp) 250.00
Max. input voltage DC (V) 1100.00
Max. input current DC (A) total 400.00
Max. input current per MPPT (A). 40
Max. short circuit current (A) total 500.00
Max. short circuit current per MPPT (A) 50
MPP max. voltage range input (V) 1000.00
Max. efficiency (%) 98.60
MPP min. voltage range input (V) 180.00
Min. temperature ambient (°C) -30
Usable capacity (kWh) 49.92
Start input voltage (V) 200
Topology transformerless
Battery cell chemistry LFP
Dangerous goods description LITHIUM ION BATTERIES
Dangerous goods Weight (net) (kg) 276.000
Dangerous goods class 9
Dangerous goods transportation category 2
UN No. 3480
Dangerous goods packaging type 4G
Manufacturer Sungrow
Manufacturer item name SH125CX-V11*STC12.5-V1*IEC_PK Accessory (Master)
Intrastat country of origin China
Intrastat product number (HS-code) 85076000
Classification code M4
Tunnel restriction code (E)
Weight incl. packaging (Kg) 706.500
Weight without packaging (kg) 563.000